Compatibility
with drive systems
|
|
 |
LSA alternators are compatible
with engine drive systems, whether in regard to electrical power,
torsional compatibility, coupling characteristics or dynamic operation
in conjunction with the engine.
The LAM (Load Adjustment Module), which is integral with R438, R448
and R449 AVRs, facilitates load acceptance of the engine.
Alternators can be manufactured in both double and single bearing
versions with a range of easily interchangeable configurations. |
| |
|
An environmentally conscious protection
system |
|
The standard
protection for LSA alternators is IP23.
Windings are insulated to class H.
The high level of winding protection is suitable for
clean environments
up to 95% relative humidity even for
marine applications in engine rooms.
Options :
- retrofitted filters on air inlets and outlets
- protection for windings in harsh environments
- space heaters,
- stator thermal protection,
- IP 42-44 range (water-cooled or air-cooled)
. |
|
|
|
|
| |
|
| |
| Optimum
windings for greater performance |
Several types of windings are available in 50Hz and 60Hz
versions to optimise performance according to the voltage required
on site and the demands of the application.
LSA alternators are provided with a 2/3 winding pitch as standard,
and are therefore perfectly suited to installations with distorting
loads. |
|
| |
| |
| Alternators dedicated
to your specific application |
Due
to the use of modules or design modifications, LEROY-SOMER alternators
provide solutions to the most exacting applications including:
- Marine
- Telecommunications / Internet
- The gensets operation in parallel.
- Civil and military aviation (400Hz)
- Oil and gas
- Military, etc
|
 |
|
| |
| Large
and adaptable terminal box |
|
The generously proportioned terminal box allows easy access
for installation and maintenance.
- The voltage regulator can be reached via side-mounted or
front-mounted access panels.
- It becomes a simple and straightforward matter to alter
the voltage by reconnection and to connect the neutral. Current
transformers can also be easily integrated for the purpose
of parallel operation, measurement or protection.
|
|
| |
| Choosing the right
excitation system for your needs |
LEROY-SOMER offers
an incomparable range of excitation systems without slip rings
or revolving field brushes, the main systems being:
- Shunt, for three-phase and standard single-phase applications,
- AREP and Shunt+PMG, for three-phase applications when discriminating
protection or short-circuit capacity are required.
The AREP system, patented by LEROY-SOMER, is an original and
powerful system based on two auxiliary windings integrated into
the alternator’s stator, thus providing the alternator with
reliability, compactness and performance on starting and short-circuit.
|
|
| |
| Reliable
and powerful automatic voltage regulators
|
Developed
and manufactured by LEROY-SOMER, R-series automatic voltage
regulators are transistor controlled and monitored, thereby
providing quality regulation regardless of load distortions.
The voltage accuracy is +/- 0.5% in a steady state and at
constant speed. With numerous features fitted as standard, R-series
automatic voltage regulators (other than the R230) can be upgraded
with modules for parallel operation (current transformer, power
factor adjustment and R726 voltage matching) and for three-phase
detection (R731).
Encapsulated in resin, R-series regulators have optimum resistance
to vibration and harsh atmospheric conditions.
|
|
|
| |
| Excitation-AVR |
| |
R230 |
R438 |
R448 |
R449 |
| LSA42.2 |
Shunt (standard) |
AREP(option) |
|
|
| LSA43.2/44.2 |
Shunt (standard) |
AREP or SHUNT+PMG (option) |
Shunt,AREP PMG(option) |
|
| LSA46.2/47.2 |
Shunt (standard) |
|
AREP or SHUNT+PMG (option) |
|
| LSA49.1 |
|
|
AREP(standard) or PMG(option) |
|
| LSA50.1/51.2 |
|
|
|
AREP(standard) |
Reamark:
1.R230 can not use for parallel option,and R438 or R448 can be parallel use while adding C.T.
2.AREP or PMG is recommend for non-linear or distorting loads,starting asynchronous motors or short circuit capacity requiring. |
|